Philips HeartStart MRx Defibrillator – M3535A/M3536A

PHILIPS MRX DEFIBRILLATOR – M3535A/M3536A from Gopher Medical

Philips HeartStart MRx Defibrillator – M3535A/M3536A

Manufacturer:

Built to be rugged, reliable, and easy-to-use, the Philips HeartStart MRx provides industry-leading patient monitoring capabilities, superb diagnostic measurements, and CPR guidance. BiphasicDefibrillator/AED/Monitor. Philips MRx Options: 12 Lead, NIBP, SP02, IBP, TEMP, ETC02, BlueTooth, Q-CPR, External Paddles and Case.

Philips MRx Specifications

General:

Dimensions with pads 31.5 cm (W) x 21.0 cm (D) x 29.5 cm (H); (12.4 in. x 8.3 in. x 11.7 in.)
Dimensions with paddles 34.0 cm (W) x 21.0 cm (D) x 34.5 cm (H); (13.4 in. x 8.3 in. x 13.6 in.)
Weight Less than 13.2 lbs. including pads, pads cable, battery, and full roll of paper. Incremental
weight of external standard paddles and paddle tray is less than 2.5 lbs. Additional battery weighs less than 1.6 lbs.

Defibrillator

Waveform Biphasic Truncated Exponential. Waveform parameters adjusted as a function of patient impedance.
Shock Delivery Via multifunction electrode pads or paddles.

Delivered Energy Accuracy

Charge Time:

  • Less than 5 seconds to 200 Joules with a new, fully charged Lithium Ion battery pack at 25oC.
  • Less than 15 seconds when operating without a battery, using the M3539A AC power module alone at 90-100% rated mains voltage.
  • Less than 15 seconds with a new, fully charged Lithium Ion battery pack at 25oC, depleted by up to 15 200 Joule discharges.
  • Less than 25 seconds from initial power on, with a new, fully charged Lithium Ion battery pack at 25oC, depleted by up to 15 200 Joule discharges.
  • Less than 25 seconds from initial power on when operating without a battery, using the M3539A
  • AC power module alone at 90-100% rated mains voltage. Less than 30 seconds from initiation of rhythm analysis (AED Mode) with a new, fully charged Lithium Ion battery pack at 25oC, depleted by up to 15 200 Joule discharges.
  • Less than 30 seconds from initiation of rhythm analysis (AED Mode) when operating without a battery, using the M3539A AC power module alone at 90-100% rated mains voltage.

Selected Energy

Nominal Delivered Energy vs. Patient Impedance
Accuracy Load Impedance (ohms)
25 50 75 100 125 150 175.

Official Product Page : Philips MRx
FDA Notice: Philips MRx

Request a Quote

Built to be rugged, reliable, and easy-to-use, the Philips HeartStart MRx provides industry-leading patient monitoring capabilities, superb diagnostic measurements, and CPR guidance. BiphasicDefibrillator/AED/Monitor. Philips MRx Options: 12 Lead, NIBP, SP02, IBP, TEMP, ETC02, BlueTooth, Q-CPR, External Paddles and Case.

Philips MRx Specifications

General:

Dimensions with pads 31.5 cm (W) x 21.0 cm (D) x 29.5 cm (H); (12.4 in. x 8.3 in. x 11.7 in.)
Dimensions with paddles 34.0 cm (W) x 21.0 cm (D) x 34.5 cm (H); (13.4 in. x 8.3 in. x 13.6 in.)
Weight Less than 13.2 lbs. including pads, pads cable, battery, and full roll of paper. Incremental
weight of external standard paddles and paddle tray is less than 2.5 lbs. Additional battery weighs less than 1.6 lbs.

Defibrillator

Waveform Biphasic Truncated Exponential. Waveform parameters adjusted as a function of patient impedance.
Shock Delivery Via multifunction electrode pads or paddles.

Delivered Energy Accuracy

Charge Time:

  • Less than 5 seconds to 200 Joules with a new, fully charged Lithium Ion battery pack at 25oC.
  • Less than 15 seconds when operating without a battery, using the M3539A AC power module alone at 90-100% rated mains voltage.
  • Less than 15 seconds with a new, fully charged Lithium Ion battery pack at 25oC, depleted by up to 15 200 Joule discharges.
  • Less than 25 seconds from initial power on, with a new, fully charged Lithium Ion battery pack at 25oC, depleted by up to 15 200 Joule discharges.
  • Less than 25 seconds from initial power on when operating without a battery, using the M3539A
  • AC power module alone at 90-100% rated mains voltage. Less than 30 seconds from initiation of rhythm analysis (AED Mode) with a new, fully charged Lithium Ion battery pack at 25oC, depleted by up to 15 200 Joule discharges.
  • Less than 30 seconds from initiation of rhythm analysis (AED Mode) when operating without a battery, using the M3539A AC power module alone at 90-100% rated mains voltage.

Selected Energy

Nominal Delivered Energy vs. Patient Impedance
Accuracy Load Impedance (ohms)
25 50 75 100 125 150 175.

Official Product Page : Philips MRx
FDA Notice: Philips MRx